DICOM [Current Products]

DICOM Conformance Statements
These DICOM conformance Statemens provide details about the DICOM Service Classes, Information Objects and Communication protocols supported by Canon Medical Systems's Products. This information is inteded to facilitate checking compatibility and integrating these products within a DICOM compliant hospital network. Note that some variability is permitted within the DICOM Standard,so connectivity confirmation is still advised.

X-Ray

Product Name / Model NameSoftware VersionConformance Statement
Infinix Celeve-i series / Infinix-i series DFP-8000V6.20 or laterMIIXR0010EAU (PDF:758KB)
Alphenix
INFX-8000F, INFX-8000C, INFX-8000V, INFX-8000H, INFX-9000F, INFX-9000C, INFX-9000V
V8.0 or later2G985-047EN (PDF:827KB)
V8.3 or later2G985-047ENA (PDF:1.181KB)
XIDF-AWS801/B1, XIDF-AWS801/S2, XIDF-AWS801/C1 and XIDF-AWS801/C2V6.20 or laterMIIXR0024EAC (PDF:260KB)
XIDF-AWS801/B2, XIDF-AWS801/S3, XIDF-AWS801/C3 and XIDF-AWS801/C4V8.0 or later2G985-043EN (PDF:464KB)
V8.3 or later2G985-043ENA (PDF:549KB)
HDR-08AV1.00.00 or laterMIIXR0019EAC (PDF:373KB)
V1.04.01 or laterMIIXR0019EAD (PDF:374KB)
V1.31.01 or laterMIIXR0019EAE (PDF:596KB)
Ultimax-i / DREX-UI80
ZEXIRA / DREX-ZX80
KALARE / DREX-KL80
PlessartZERO / DREX-PZ10
PlessartVIVO / DREX-PV50
PlessartEX8 / DREX-W20PE8
(MODEL HDR-08A)
V1.60.04 or later2G985-056EN (PDF:964KB)
MGU-1000D/NTV1.3 or later2G985-044EN (PDF:925KB)
MGU-1000D/NS, /ND, /NM, /J1, /SB, /M1V3.00 or laterMIIXR0014EAH (PDF:529KB)
Plessart32, Plessart50 PDR-01A (The conformance statement for this model also applies to PDR-02A.)Ver.1.03 or laterMIIXR0015EAA (PDF:312KB)
DRAD-3000EV3.20 or laterMIIXR0017EAC (PDF:447KB)
SXT-2000ACXVIEW 3.0.1 or later2G985-030ENA (PDF:515KB)
TDR-2010AV3.30 or laterMIIXR0020EAA (PDF:332KB)
ZEXIRA PDR-04A/01,/02V3.00 or later2G985-005ENA (PDF:630KB)

Computed Tomography

Product Name / Model NameSoftware VersionConformance Statement
Aquilion Precision
TSX-304A
V8.8 or later2G985-051EN(PDF:3.9MB)
Aquilion, Aquilion ONE,
Aquilion PRIME, Alexion, Astelion
TSX-101A, TSX-301A, TSX-301B, TSX-301C, TSX-302A, TSX-201A, TSX-032A, TSX-033A, TSX-034A, TSX-303A
V6.0 or laterMIICT0058EAC (PDF:881KB)
Aquilion, Alexion, Astelion, Aquilion ONE
TSX-101A,TSX-301A,TSX-301B,TSX-301C,TSX-302A,TSX-303A,TSX-201A,TSX-032A,TSX-033A,TSX-034A,TSX-035A,TSX-305A
V7.0 or later2G985-019ENA (PDF:1,062KB)
Aquilion, Aquilion ONE
TSX-301A,TSX-301B,TSX-301C,TSX-305A
V8.0 or later2G985-014EN A(PDF:1,055KB)
Aquilion, Aquilion ONE
TSX-301A,TSX-301B,TSX-301C,TSX-305A,TSX-303A,TSX-036A,TSX-303B
V8.1 or later2G985-033ENA (PDF:1,060KB)
Aquilion, Aquilion ONE
TSX-301A,TSX-301B,TSX-301C,TSX-305A
V8.9 or later2G985-050EN (PDF:3.71MB)
Aquilion ONE
TSX-305A, TSX-306A
V10.0 or later2G985-055EN(PDF:1.9MB)
Aquilion Start
TSX-037A
V9.0 or later2G985-053EN(PDF:3.58MB)
VitreaPlease check at vitalimages.com (a separate window will open)

Magnetic Resonance Imaging

Product Name / Model NameSoftware VersionConformance Statement
Vantage Elan,
Vantage Titan
MRT-2020, MRT-1504,
MRT-1510, MRT-2004,
MRT-3010
V3.0 and V3.1 2G985-002ENB (PDF:833KB) 
V2.60 and V3.52G985-003ENC (PDF:846KB)
Vantage Elan,
Vantage Titan
Vantage Galan
MRT-2020, MRT-1504,
MRT-1510, MRT-2004,
MRT-3010, MRT-3020
V4.02G985-021ENB (PDF:979KB)
Vantage Orian,
Vantage Galan
MRT-1550, MRT-3020
V4.5, V5.0 and V6.02G985-038ENB (PDF:1.19MB)

Ultrasound

Product Name / Model NameSoftware VersionConformance Statement
Aplio i900 TUS-AI900
Aplio i800 TUS-AI800
Aplio i700 TUS-AI700
Aplio i600 TUS-AI600
V1.6/V1.7/V1.82G985-016ENF (PDF:7.77MB)
V2.02G985-016ENG (PDF:8.23MB)
V2.52G985-016ENH (PDF:8.17MB)
V3.02G985-016ENI (PDF:8.27MB)
V4.0 or later2G985-016ENJ (PDF:13.0MB)
Aplio a550 CUS-AA550
Aplio a450 CUS-AA450
V1.32G985-039EN (PDF:8.51MB)
V2.0 or later2G985-039ENA(PDF:12.9MB)
Aplio a CUS-AA000V1.0 or later2G985-039ENA(PDF:12.9MB)
Aplio 500 TUS-A500
Aplio 400 TUS-A400
Aplio 300 TUS-A300
V6.60/V6.70/V6.802G985-007END (PDF:7.46MB)
V7.00 or later2G985-007ENE (PDF:6.46MB)
Xario 200G CUS-X200G
Xario 100G CUS-X100G
1.1 or later2G985-041EN (PDF:7.15MB)
Xario 200 TUS-X200
Xario 100 TUS-X100
V5.6/V5.7/V5.82G985-008END (PDF:7.45MB)
V6.0 or later2G985-008ENE (PDF:7.39MB)
Xario 100 TUS-X100SV4.0 or later2G985-017ENA (PDF:3.54MB)
Viamo c100 TUS-VC100V1.1 or later2G985-034ENA (PDF:404KB)
Viamo sv7 CUS-VSV7V1.52G985-040EN (PDF:646KB)
V3.1 or later2G985-040ENA (PDF:930KB)
Aplio Artida
SSH-880CV
V3.20 or laterMIIUS0048EAD (PDF:4.04MB)
UltraExtendFX
TUW-U001
V5.00 or later2G985-004ENA (PDF:3.34MB)
UltraExtend
USWS-900R
V1.00 or laterMIIUS0037EAA (PDF:252KB)

Nuclear Medicine

Product Name / Model NameSoftware VersionConformance Statement
Celesteion
PCA-9000A
V6.2 or laterMIICT0059EAA (PDF:945KB)
V6.4 or later2G985-031ENA (PDF:1.2MB)
V6.5 or later2G985-046EN (PDF:1.4MB)

SERVER / WORKSTATION

Product Name / Model NameSoftware VersionConformance Statement
TFS-01V1.00 or laterMIIMS0015EAC (PDF:306KB)
V1.80 or laterMIIMS0015EAD (PDF:374KB)
V2.60JR000 or laterMIIMS0015EAE (PDF:411KB)
V3.2 SP0000J or later2G985-028ENA (PDF:443KB)
V3.3 SP0000J or later2G985-028ENB (PDF:451KB)
TCS-10V1.00 or laterMIIMS0020EAB (PDF:405KB)
V1.20 or laterMIIMS0020EAC (PDF:457KB)
STMH-005, SVIW-TMH05V1.0 SP0000J or later2G985-011ENA (PDF:363KB)
V1.1 SP0000J or later2G985-011ENB (PDF:397KB)
V2.1 SP0000J or later2G985-048EN (PDF:402KB)
VAS-01V7.4 SP0000J or later2G985-029ENA (PDF:549KB)
Abierto VNA
HCBA-01
V1.0 or later2G985-035ENA (PDF:331KB)
V1.1 or later2G985-035ENB (PDF:656KB)
V1.2 or later2G985-035ENC (PDF:437KB)
VitreaPlease check at vitalimages.com (a separate window will open)

Adobe Reader is required to view the document. Click here to download the latest version. (a separate window will open)