AiCE DLR combined with SEMAR for post-operative evaluation of ankle with internal fixation, demonstrating excellent visualization of implant, bone and adjoining soft-tissue through significant artifact and noise reduction.
View Scan ParametersScan Mode | Ultra helical |
Collimation | 0.5mm x 80 |
kVp | 135 |
mAs | EC |
Rotation Time | 1.0s |
Scan Range | 430.0mm |
Reconstruction | AiCE Bone |
CTDlvol | 9.0mGy |
DLP | 427.10mGy·cm |
A CT scan of the right ankle was performed with SEMAR. It demonstrates a complex distal tibia and fibula fractures with fixation device.
View Scan ParametersScan Mode | Wide Volume |
Collimation | 0.5mm x 80 |
kVp | 120 |
mAs | 100 |
Rotation Time | 0.5s |
Scan Range | 188.0mm |
Reconstruction | AIDR 3D |
CTDlvol | 8.6mGy |
DLP | 161.5mGy·cm |
Ultra Helical CT of bilateral hips and femurs. Artifact inherent with metallic bilateral hip replacements and surgical fixation of left femoral fracture is dramatically reduced with SEMAR (Single Energy Metal Artifact Reduction).
View Scan ParametersScan Mode | Ultra-Helical |
Collimation | 0.5mm x 80 |
kVp | 120 |
mAs | SUREExposure |
Rotation Time | 0.5s |
Scan Range | 670.0mm |
Reconstruction | AIDR 3D |
CTDlvol | 4.7mGy |
DLP | 337.5mGy·cm |
A CT scan of the knee was performed with SEMAR and it demonstrates an internal fixation device.
View Scan ParametersScan Mode | Wide Volume |
Collimation | 0.5mm x 80 |
kVp | 135 |
mAs | SUREExposure |
Rotation Time | 0.5s |
Scan Range | 225.0mm |
Reconstruction | AIDR 3D |
CTDlvol | 8.5mGy |
DLP | 192.0mGy·cm |
3D and MPR demonstrate multiple herniated disks.
View Scan ParametersScan Mode | Ultra-Helical |
Collimation | 0.5mm x 80 |
kVp | 135 |
mAs | SUREExposure |
Rotation Time | 0.75s |
Scan Range | 243.0mm |
Reconstruction | AIDR 3D |
CTDIvol | 13.2mGy |
DLP | 377.9mGy·cm |
Effective Dose | 5.66mSv |
k-factor | 0.015 (AAPM Report 96) |
CT scan of the left shoulder demonstrates bone spurs and joint space narrowing compatible with osteoarthritis.
View Scan ParametersScan Mode | Ultra-Helical |
Collimation | 0.5mm x 80 |
kVp | 120 |
mAs | SUREExposure |
Rotation Time | 0.75s |
Scan Range | 198.0mm |
Reconstruction | AIDR 3D |
CTDlvol | 10.1mGy |
DLP | 244.4mGy·cm |
Effective Dose | 3.4mSv |
k-factor | 0.014 (AAPM Report 96) |
DE analysis demonstrates monosodium urate crystals (MSU) and volume estimate of the urate burden.
View Scan ParametersScan Mode | DE-Helical |
Collimation | 0.5mm x 80 |
kVp | 80/135 |
mAs | 50/290 |
Rotation Time | 0.5s |
Scan Range | 306.0mm |
Reconstruction | AIDR 3D |
CTDIvol | 10.0mGy |
DLP | 311.3mGy·cm |
CTA demonstrates a radial artery aneurysm.
View Scan ParametersScan Mode | Ultra-Helical |
Collimation | 0.5mm x 80 |
kVp | 120 |
mAs | SUREExposure |
Rotation Time | 0.5s |
Scan Range | 264.0mm |
Reconstruction | AIDR 3D |
CTDIvol | 4.4mGy |
DLP | 134.7mGy·cm |